Multilife Testing Bearing: 7 longitudinal & 7 shear lubricant: 460WT grease with 1/3rd fill Date: 11/03/2021 Acquisition Software: FMS 1.3.15 Active Channels: 7 Sensors: 7 longitudinal 10 MHz, 1 shear 5MHz Ch1 - Ch8 Range: 9 Ch1 - Ch8 Pulse Width: 7 Ch1 - Ch7 Delay: 690, chn8: 1242 Ch1 - Ch7 Filter: 6 Pulse Voltage: 100 Pulse Rate: 72306 Capture Time: Interval of 5 seconds on 25 seconds off for 30 minute peridos Test notes/comments: first capture at stationary bearing start temp around 23C test conditions finished applying after 2mins 10 seconds visibly steeper increase in temperature at the beginning of the test sun on and off Big T2 spike around 2hr when sun was on rig hydraulic screach around the 09:35, 19:05 captures bearing stopped rotating, after demmand removed, a lot quicker than in the 20 rpm case capture times C1 = 00:00:00 - 00:29:35 d C2 = 00:30:00 - 00:59:35 d c3 = 01:00:00 - 01:29:35 d c4 = 01:30:00 - 01:59:35 d c5 = 02:00:00 - 02:09:35 d 130 minutes of data taken in total