Multilife Testing Bearing: 7 longitudinal & 7 shear lubricant: 460WT grease with 1/3rd fill Date: 16/03/2021 Acquisition Software: FMS 1.3.15 Active Channels: 7 Sensors: 7 longitudinal 10 MHz, 1 shear 5MHz Ch1 - Ch8 Range: 9 Ch1 - Ch8 Pulse Width: 7 Ch1 - Ch7 Delay: 690, chn8: 1242 Ch1 - Ch7 Filter: 6 Pulse Voltage: 100 Pulse Rate: 72306 Capture Time: Interval of 5 seconds on 25 seconds off for 30 minute peridos Test notes/comments: starting temp approx 27C ramp up :20rpm, 400kN, 40 rpm, 60 rpm, 80 rpm first capture at stationary bearing Test conditions after 5 min 45 rainy day (no sun) extremely steep temperature gradient after hitting 100rpm laptop charger was in same extension cables repositioned around 3hr 15-16 approx because a vibration in cable point where resting on rig was noticed 4hr 36 approx some bounce noticed in rig, video taken from strongest side but still present on other side clank around 5hr 05min, could be from outside capture times C1 = 00:00:00 - 00:29:35 d C2 = 00:30:00 - 00:59:35 d sun come ot at end c3 = 01:00:00 - 01:29:35 d hydraulic loading towards last minute of capture c4 = 01:30:00 - 01:59:35 d c5 = 02:00:00 - 02:29:35 d c6 = 02:30:00 - 02:59:35 d c7 = 03:00:00 - 03:29:35 d c8 = 03:30:00 - 03:59:35 d c9 = 04:00:00 - 04:29:35 d c10 = 04:30:00 - 04:59:35 d c11 = 05:00:00 - 05:29:35 d c12 = 05:30:00 - 05:30:00 d last capture is of stationary bearing unloading reduced to 20 rpm load removed - as load came off rpm jumped up before reducing again dor some reason